Comparison of different devices for predicting the lean meat percentage of pig carcasses
View/Open
Other authors
Publication date
2009-06Abstract
Lean meat percentage (LMP) is the criterion for carcass classification and it must be measured on line objectively. The aim of this work was to compare the error of the prediction (RMSEP) of the LMP measured with the following different devices: Fat-O-Meat’er (FOM), UltraFOM (UFOM), AUTOFOM and -VCS2000. For this reason the same 99 carcasses were measured using all 4 apparatus and dissected according to the European Reference Method. Moreover a subsample of the carcasses (n=77) were fully scanned with a X-ray Computed Tomography equipment (CT). The RMSEP calculated with cross validation leave-one-out was lower for FOM and AUTOFOM (1.8% and 1.9%, respectively) and higher for UFOM and VCS2000 (2.3% for both devices). The error obtained with CT was the lowest (0.96%) in accordance with previous results, but CT cannot be used on line. It can be concluded that FOM and AUTOFOM presented better accuracy than UFOM and VCS2000.
Document Type
Article
Language
English
Keywords
Pages
13 p.
Publisher
Elsevier B.V.
Program
Qualitat i Tecnologia Alimentària
Recommended citation
This citation was generated automatically.
This item appears in the following Collection(s)
- ARTICLES CIENTÍFICS [3467]
Except where otherwise noted, this item's license is described as http://creativecommons.org/licenses/by-nc-nd/2.5/